Fiber Optic Cables
Cáp mạng 700009855 | P-002-DS-5L-FSUAQ
Các thông số kĩ thuật và thông tin chi tiết về cấu tạo, tính năng nổi bật và chính sách hỗ trợ dòng sản phẩm Cáp mạng 700009855 | P-002-DS-5L-FSUAQ
-
1
Giảm giá 50% gói bảo hành
-
2
Giảm đến 1,500,000đ khi tham gia thu cũ đổi mới (Không áp dụng kèm giảm giá qua VNPay, Moca)
-
3
Lorem ipsum dolor sit amet consectetur adipisicing elit. Consectetur, doloremque?
-
4
Lorem ipsum dolor sit amet consectetur adipisicing.

PHÂN LOẠI SẢN PHẨM
| Regional Availability |
Asia | Australia/New Zealand | Latin America | Middle East/Africa | North America |
| Portfolio |
CommScope® |
| Product Type |
Fiber indoor cable |
| Product Series |
P-DS |
THÔNG SỐ KỸ THUẬT CHUNG
| Cable Type |
Distribution |
| Construction Type |
Non-armored |
| Fiber Type, quantity |
2 |
| Jacket Color |
Aqua |
| Jacket Marking |
Feet |
| Subunit Type |
Gel-free |
| Total Fiber Count |
2 |
KÍCH THƯỚC
| Diameter Over Jacket |
3.76 mm | 0.148 in |
Representative Image
| Click on image to enlarge. |
|
Mechanical Specifications
| Minimum Bend Radius, loaded |
56 mm | 2.205 in |
| Minimum Bend Radius, unloaded |
38 mm | 1.496 in |
| Tensile Load, long term, maximum |
200 N | 44.962 lbf |
| Tensile Load, short term, maximum |
667 N | 149.948 lbf |
| Compression |
10 N/mm | 57.101 lb/in |
| Compression Test Method |
FOTP-41 | IEC 60794-1 E3 |
| Flex |
100 cycles |
| Flex Test Method |
FOTP-104 | IEC 60794-1 E6 |
| Impact |
5.88 N-m | 52.042 in lb |
| Impact Test Method |
FOTP-25 | IEC 60794-1 E4 |
| Strain |
See long and short term tensile loads |
| Strain Test Method |
FOTP-33 | IEC 60794-1 E1 |
| Twist |
10 cycles |
| Twist Test Method |
FOTP-85 | IEC 60794-1 E7 |
| Vertical Rise, maximum |
500 m | 1640.42 ft |
Optical Specifications
| Fiber Type |
OM3, LazrSPEED® 300 | OM3, LazrSPEED® 300 |
Environmental Specifications
| Installation temperature |
0 °C to +70 °C (+32 °F to +158 °F) |
| Operating Temperature |
-20 °C to +70 °C (-4 °F to +158 °F) |
| Storage Temperature |
-40 °C to +70 °C (-40 °F to +158 °F) |
| Cable Qualification Standards |
ANSI/ICEA S-83-596 | Telcordia GR-409 |
| Environmental Space |
Plenum |
| Flame Test Listing |
NEC OFNP (ETL) and c(ETL) |
| Flame Test Method |
NFPA 130 | NFPA 262 |
Environmental Test Specifications
| Heat Age |
-20 °C to +85 °C (-4 °F to +185 °F) |
| Heat Age Test Method |
IEC 60794-1 F9 |
| Low High Bend |
-20 °C to +70 °C (-4 °F to +158 °F) |
| Low High Bend Test Method |
FOTP-37 | IEC 60794-1 E11 |
| Temperature Cycle |
-20 °C to +70 °C (-4 °F to +158 °F) |
| Temperature Cycle Test Method |
FOTP-3 | IEC 60794-1 F1 |
BAO BÌ VÀ TRỌNG LƯỢNG
| Cable weight |
13 kg/km | 8.736 lb/kft |
Regulatory Compliance/Certifications
| Agency |
Classification |
ISO 9001:2015  |
Designed, manufactured and/or distributed under this quality management system |
| ROHS |
Compliant |
CHINA-ROHS  |
Below maximum concentration value |
| REACH-SVHC |
Compliant as per SVHC revision on www.commscope.com/ProductCompliance |